Helium Leak Tester for CTC

Proof Pressure

35 bar

HMI Adjustable

Leak Rate

10-5

100% Helium Test

Configuration

Double 

Chamber Output

Installed

Sweden

CTC Facility

Reference Project: Heat Pump Integrity

Integrated Validation for Green Heating Solutions.

Nolek partnered with CTC (Enertech) in Sweden to deliver a high-capacity Helium Leak Tester optimized for the next generation of residential heat pumps. This advanced system utilizes a double-chamber pod design powered by a single test circuit, ensuring 100% component safety while integrating Nolek’s recovery technology to maximize operational sustainability.

  The Challenge

Validating complex heat pump circuits at pressures up to 35 bar while maintaining high industrial throughput and zero-defect quality standards.

 
◈ The Solution

A high-precision double vacuum chamber system featuring Nolek HRS, allowing for 24/7 automated testing with minimal Helium tracer gas waste.

Sustainable Industrial Excellence

High-performance Helium validation designed for high-volume climate solution production.

Double Chamber

HRS Sustainability

Precision Load

Helium Leak Tester for CTC.

Technical Specifications

Precision tracer gas validation for high-efficiency heat pump systems.

Specification

Details

Test Piece

 Heat Pump (Renewable Heating System)

Key Features

Double chamber with one test system

Recovery Technology

Helium recovery system via Nolek HRS

Proof Test Pressure

Up to 35 bar (Adjustable from HMI)

Helium Test Pressure

11 Bar (Tracer gas)

Max Leak Rate

2 x 10-5 mbar·l/s @ 100% Helium

Installed Location

CTC Sweden (Ljunby)

Industry

HVAC / Sustainable Energy Solutions